J Air Waste Manag Assoc. 2026 Jul 21:1-13. doi: 10.1080/10962247.2026.2626414. Online ahead of print.
ABSTRACT
Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). We analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial to assess the influence that different methods of I estimations have on eBC measures. We compared eBC measurements using filter-specific I values (Method 1) to those using three other methods of I estimation: the lab blank scan from a given session (Method 2), the average of all pre-sample filter scans (Method 3), and the average of all lab blank filter scans (Method 4). We assessed the agreement between Method 1 and the alternative methods using Bland-Altman analysis. We also assessed the relationship between Method 1 and the alternative methods across the complete measurement range and after stratifying exposure data into quartiles according to Method 1 eBC exposures. The mean (SD) personal eBC exposure for Method 1 was 7.8 μg/m3 (5.9), and exposures ranged from 1.3 to 46.8 μg/m3. Compared to Method 1, eBC using Methods 2, 3, and 4 were higher by 0.7 μg/m3, 0.1 μg/m3, and 0.7 μg/m3, respectively. The performances of linear regression models between Method 1 and all other methods were moderate to strong (R2 range: 0.42-0.93) in the second, third, and fourth quartiles; however, the models in the first quartile (eBC range: 1.3-2.9 μg/m3) performed poorly (R2 = 0.25-0.26), with error approximately 25% of the mean. Our findings suggest that, in most instances, conventional methods for obtaining I values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.Implications: Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). To assess the influence that different methods of I estimations have on eBC measures, we analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial. Our findings suggest that, in most instances, conventional methods for obtaining I values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.
PMID:42480071 | DOI:10.1080/10962247.2026.2626414